What is Adsorption? Adsorption is a process that occurs when a gas or liquid solute accumulates on the surface of a solid, forming a molecular or atomic film (the adsorbate). The carbon utilized for radioactive iodine removal is nuclear grade 8x16 mesh and is impregnated with TEDA to improve retention of radio-iodines. RPS offers adsorbers in both circular and square cross-sections. CUSTOM SIZES AND CONFIGURATIONS AVAILABLE UPON REQUEST. |
||||
Part Number |
Description | |||
|
||||
C103585 | Residence Time Type Rated Airflow Rated Pressure Drop Nominal Size (Inches) Frame Material Notes |
..... ..... ..... ..... ..... ..... ..... |
0.286 seconds at 500 CFM, 0.125 seconds at 1,140 CFM Nuclear-grade 8 x16 mesh, impregnated with TEDA 1,000 CFM 1.35" wg. 24 x 24 x 16 High-Impact Plastic ASME NQA-1 For use in C103595 |
|
|
||||
AG01 | Residence Time Type Rated Airflow Rated Pressure Drop Nominal Size (Inches) Frame Material Notes |
..... ..... ..... ..... ..... ..... ..... |
0.250 seconds at 1,000 CFM Nuclear-grade 8 x16 mesh, impregnated with TEDA 1,000 CFM 1.0” wg. 24 x 24 x 22 304 Stainless Steel Bolting flange on both the upstream and downstream faces US NRC Reg., Guide 1.52 and ANSI/ASME N509 For use in FM24 |
|
|
||||
AG02 | Residence Time Type Rated Airflow Rated Pressure Drop Nominal Size (Inches) Frame Material Notes |
..... ..... ..... ..... ..... ..... ..... |
0.250 seconds at 500 CFM, 0.125 seconds at 1,000 CFM Nuclear-grade 8 x16 mesh, impregnated with TEDA 1,000 CFM 1.0” wg. 24 x 24 x 16 304 Stainless Steel Gasket seal on both upstream and downstream faces US NRC Reg., Guide 1.52 and ANSI/ASME N509 For use in FM19, FM23, and FM25 |
|
|
||||
AK43 | Residence Time Type Rated Airflow Rated Pressure Drop Nominal Size (Inches) Frame Material Notes |
..... ..... ..... ..... ..... ..... ..... |
0.850 seconds at 1,000 CFM Technical grade activated carbon 1,000 CFM 3.2” wg. 30 x 34 x 47 Carbon steel, epoxy painted Not rated for nuclear (radio-iodine) applications Standard Adsorbent Fill: 400lbs 8” OD duct connection collar |
|
|
||||
AK45 | Residence Time Type Rated Airflow Rated Pressure Drop Nominal Size (Inches) Frame Material Notes |
..... ..... ..... ..... ..... ..... ..... |
1.130 seconds at 3,000 CFM Technical grade activated carbon 3,000 CFM 4.8” wg. 50 x 46 x 66 Carbon steel, epoxy painted Not rated for nuclear (radio-iodine) applications Standard Adsorbent Fill: 1,600lbs 12” OD duct collar |
|
|
||||